- over 480,000 plumbing related posts - Plbg.com - the popular plumbing forum. Ask any toilet, sink, faucet, pump, water quality and plumbing related questions. Baxi Luna HT330 Boiler Pressure Author: Mitch581 (NY) Hi, It's mitch again from[...]
Date Published:


Untitled


[...]
Date Published:


Author: Mitch581 (NY) Hi, It's mitch again from Western


Author: Mitch581 (NY) Hi, It's mitch again from Western NY. We are still enjoying our Baxi Luna HT330 however I'm getting more thatn 1.5 bars on the boiler pressure on the gauge. When it reaches around 2 of course (29.0075+ PSI) it drains out of the[...]
Date Published:


Untitled


[...]
Date Published:


Author: tommyb (NY) it could be the fill valve is faulty or


Author: tommyb (NY) it could be the fill valve is faulty or needs to be set lower....also youe expansion tank if you have one needs to be drained or your ex-trol tank lost its charge...[...]
Date Published:


Untitled


[...]
Date Published:


Author: Mitch581 (NY) One thing I did try was to turn the


Author: Mitch581 (NY) One thing I did try was to turn the screw counter clockwise on the PRV to try and reduce the pressure going into the system. When I opened the valve it still shot right up to just over 2 bars. Could the PRV spring be bad? Is there[...]
Date Published:


Untitled


[...]
Date Published:


Author: Mitch581 (NY) I think what I'll try is shutting down


Author: Mitch581 (NY) I think what I'll try is shutting down the system, drop the water pressure to zero on the system side and check the air on the expansion tank. If that doesn't work then I'll check the PRV and see if there is a problem with that.[...]
Date Published:


Untitled


[...]
Date Published:


Author: packy shouldn't have gone bad in 3 years, but the


Author: packy shouldn't have gone bad in 3 years, but the information you have given leads to a bad PRV. pretty easy replacement if there are isolation valves on either side.[...]
Date Published:


Untitled


[...]
Date Published:


Author: Mitch581 (NY) Thanks, there are isolation valves on


Author: Mitch581 (NY) Thanks, there are isolation valves on both sides. The lever doesn't move as freely as it should and the amount of water coming in doesn't seem to be reduced by counter turning the head screw. I may give that a try first. The[...]