Replaces MS-1 and PS-1 sensors.
Color-coded RED with a quick-disconnect 12-inch lead that
connects to a standard 20-foot sensor cable for use with M-1,
MB-1, M-2A, S-1, S-1A and S-2A fume detectors.
Plug-in connectors eliminate wire routing during installation or
sensor replacement.
This is a simple, single channel propane fume detector that
features a plug-in sensor and a Var-A-Brite indicator lamp that
brightens during the day and soften at night.
The standard two-inch display module features a circuitry test
and alarm horn silence function.
Complete unit includes display module, one propane sensor and 20
feet of connector wire. On / off switch opens and closes solenoid
with the touch of a button.
A microprocessor-controlled two-channel monitor with automatic
solenoid valve on / off switch.
Its features include low current draw, plug-in sensors (second
sensor optional), display module fault light / alarm and fault
light / alarm to indicate a malfunction in either one of the
sensors. (Fault indicators show that the module or sensors are
not working and may need repair.)
A "press to test" button for each channel confirms function.
1 MS-2 sensor and 1 SV-1 solenoid valve included.
The system is calibrated at 20% LEL (lower explosive limit) to
eliminate most nuisance alarms while allowing enough time to take
action.
Module size: 4 3/4" x 3 3/4" x 7/8"
A microprocessor-controlled, two-channel gasoline fume detector
in a low profile, water resistant design.
Its features include two-channel monitoring capability, plug-in
sensors (second sensor optional), fault light alarm, fault lights
to indicate a malfunction in either the module or one of the
sensors.
A "press to test" button for each channel indicates either an OK
or Danger condition.
An Alarm Silence button deactivates the alarm horn .
The system is calibrated to eliminate most nuisance alarms while
allowing enough time to take action.
Includes the features of the M-2A:
The MB-2 adds automatic bilge blower control. The blower is
automatically started when a fume level of 16 to 20% LEL (lower
explosive limit) is reached and remains on until fume level is
safely lowered.
A 30 amp relay is standard.
The MB-2 system also includes a test button at the display module
to activate the warning lamp, alarm horn and blower motor.
Provides over-current protection for system wiring.
For safe operation of your inverter or inverter/charger system,
Xantrex? Battery Fuse and Holder is a recommended accessory that
offers over-current protection for the cable running between the
inverter and battery power source. The Battery Fuse and Holder
has a cover that protects from inadvertent contact with the
battery fuse and posts, and the fuse is Class-T rated to allow
for momentary surges without blowing.
As current passes through any cable, heat is generated. If the
inverter draws more current than the cable can handle due to
heavy loads, excessive heat is produced. The fuse can handle a
certain amount of excess current but is designed to blow when the
safe limits are exceeded, protecting the cable from deterioration
or permanent damage. Proper sizing of the cable and fuse are
important in ensuring that these hazards are avoided. For
specific recommendations, refer to the inverter or
inverter/charger owner?s manual.
Product Features
Specifications
The CMD-4MR carbon monoxide detector is available when generator shutdown and multiple location warning are not desired. 12 VDC operation. Features a state-of-the-art sensor that is unaffected by common cleaning solvents. Lowest current draw of any Fireboy-Xintex CO Detector. UL 2034 Listed for Marine use.
LinkPRO Battery Monitor
Battery Status At A Glance
The LinkPRO can measure currents up to 10,000 Amps. It selectively displays voltage, charge and discharge current, consumed amphours, remaining battery capacity and the time remaining of your battery bank. It is equipped with an internal programmable alarm relay, to run a generator when needed or to turn off devices when the battery voltage exceeds programmable boundaries.
Note: The LinkPRO Battery Monitor is the direct replacement of XBM Battery Monitor with expanded features.
Description
Defining the amount of energy available in a battery is a complex task since battery age, discharge current and temperature all influence the actual battery capacity. High performance measuring circuits, along with complex software algorithms, are used to exactly determine the remaining battery capacity. A new shunt selection feature enables the LinkPRO to measure currents up to 10,000 Amps.
The LinkPRO selectively displays voltage, charge and discharge current, consumed amphours, remaining battery capacity and the time remaining of your battery bank. Using a clear backlit LCD Display and an intuitive user interface, all parameters can be recalled with just a button press. A second battery input is also provided to monitor voltage on a second battery.
It is equipped with an internal programmable alarm relay, to run a generator when needed or to turn off devices when the battery voltage exceeds programmable boundaries.
Performance Features
The C-1 is a simple solenoid valve control that features an
"ON/OFF" and LED that illuminates when the solenoid valve is
open. Includes one SV-1 1/4" solenoid valve.
The solenoid valve is normally closed and must have power applied
to open it.
Mount the solenoid valve on the tank side of the regulator for
LPG installations.
12 VDC operation.
Display size is 4.75" x 3.75" x 7/8".
The CMD-4MR-RLY is the most advanced CO detector available from
Fireboy-Xintex. It features automatic generator shutdown
capability. When dangerous CO levels are detected, the
CMD-4MR-RLY shuts down the generator, a common source of CO. This
detector also features multiple location warning, allowing up to
six detectors to be linked in series. When one detector alarms,
all connected detectors will alarm to alert boat inhabitants in
other locations to the presence of CO. Features a
state-of-the-art sensor that is unaffected by common cleaning
solvents. 12 VDC operation. Low current draw. UL 2034 Listed for
Marine use.
An ideal single channel gasoline fume detector, the M-1 features
high-tech styling, compact size, circuitry Test and alarm horn
Mute functions.
The power on indicator lamp automatically increases in brightness
during daylight and softens at night.
The M-1 package includes a standard two-inch display unit with
gasoline sensor and twenty feet of plug-together lead. In
addition to gas fumes, the M-1 can also detect high
concentrations of battery hydrogen or engine exhaust.
Description
The Freedom SW 2000 inverter/charger features pure sine wave
output and power factor corrected multi-stage charging to meet
power needs of today?s sensitive and sophisticated electronics.
It provides 2000 watts of continuous sine wave power to operate
commonly used AC-powered electronics such as plasma television
sets, microwaves, entertainment systems, computers, printers,
power tools, mini refrigerator and much more.
Application
Product Features
*when used with On/Off Remote Switch
Protection Features
FREEDOM SW 2000 Sine Wave Inverter/Charger
Electrical Specifications - Inverter
Output power (continuous at 30°:C):2000 W
Surge rating (10 seconds):4000 W
Output frequency:60 Hz ± 0.2 Hz
Output voltage:120 Vac
Output wave form:Pure sine wave
Optimal efficiency:90%
No-load power draw (inverting):2 Adc
Input DC voltage range:11 - 15 Vdc
AC connections:Single
Low battery voltage cut-off 10.5 V, 11.8 V (selectable)
Output current 100 A
Output voltage 12 Vdc
Output voltage range 10.0 - 15.5 Vdc
Charge control 3 stage with manual equalize
Charge temperature compensation Battery temperature sensor (included)
Optimal Efficiency > 85%
AC input power factor (full power) > 0.98
Input current (for 100/150 A charging) 15.8 Aac
Input AC voltage 120 Vac
Input AC voltage range 95 - 140 Vac
Dead battery charge > 8.5 Vdc
Compatible battery types Flooded / gel / AGM /
Transfer relay rating 30 A, 120 Vac
Transfer time (AC to inverter and inverter to AC) 20 ms
Optimal operating temperature range - 4°:F to 122°:F (- 20°:C to 50°:C)
Storage ambient temperature range - 4°:F to 167°:F (- 20°:C to 75°:C)
Optimal operating temperature range 0°:C to 50°:C
Unit dimensions (H x W x L) 7.75 x 13.5 x 15.25" (19.7 x 34.3 x 38.7 cm)
Unit weight 27.5 kg (60.5 lbs)
Warranty 2 years
Master carton quantity 1
Master carton dimensions 11.8 x 17.1 x 20.5" (30 x 43.5 x 52.2 cm)
Master carton weight 30 kg (66 lbs)
Part Number 815-2000
Freedom SW on/off remote panel Part# 808-9002 - INCLUDED
Battery Temperature Sensor Part# 808-0232-01 - INCLUDED
ETL certified to CSA 107.1, UL458 with marine supplement**, FCC Class B
Electrical Specifications - Charger
General Specifications
Accessories
Regulatory & Environmental Compliance
**When used with the Drip Shield. Drip Shield sold separately. Note: Specifications subject to change without notic
LinkLITE Battery Monitor
Battery Status At A Glance
The LinkLITE battery monitor can measure currents up to 1,000Amps. It selectively displays voltage, charge and discharge current, consumed amphours and remaining battery capacity. It is equipped with an internal programmable alarm relay, to run a generator when needed or to turn off devices when the battery voltage exceeds programmable boundaries.
Description
Defining the amount of energy available in a battery is a complex task since battery age, discharge current and temperature all influence the actual battery capacity. High performance measuring circuits, along with complex software algorithms, are used to exactly determine the remaining battery capacity. A new shunt selection feature enables the LinkLITE to measure currents up to 1,000Amps respectively.
The LinkLITE selectively displays voltage, charge and discharge current, consumed amphours and remaining battery capacity. Using a clear backlit LCD Display and an intuitive user interface, all parameters can be recalled with just a button press. A second battery input is also provided to monitor voltage on a second battery.
It is equipped with an internal programmable alarm relay, to run a generator when needed or to turn off devices when the battery voltage exceeds programmable boundaries.
Performance Features
Xantrex' Battery Temperature Sensor is designed for use with DR
and UX Inverters and C Series Charge Controllers. The BTS mounts
on a terminal post of a battery in a bank or on the side of a
battery and measures its temperature. It sends precise
information to the charger or charge controller, which
automatically adjusts voltage to ensure full battery charge
depending on the ambient temperature of your battery
installation. The BTS is standard on SW and PS Inverters.
Mobile Power for Trucks, RVs and Boats
XPower Inverters connect easily to 12 volt batteries to provide AC power for a variety of medium to heavy duty applications. Designed for easy installation and operation, the XPower inverters provide a reliable source of power onboard trucks, RVs and boats to run home appliances, consumer electronics, entertainiment systems, power tools, office equipment and much more. They are also suitable for small contractors who need to operate handheld power tools from their van or pick-up truck. The powerful 5000-watt model has four GFCI oulets for multiple loads and an easy-to-read digital display for instant system information. All models except for the 5000 meet the stringent UL458 regulatory requirements.
Product Features
Protection Features
Product Applications
| Electrical Specifications | Inverter 1000 | Inverter 1500 | Inverter 3000 | Inverter 5000 |
| Surge capacity (peak) | 2000 watts | 3000 watts | 5000 watts | 10000 watts |
| Max. continuous power | 1000 watts | 1500 watts | 3000 watts | 5000 watts |
| AC output voltage | 115VAC +/- 5% | 115VAC +/- 5% | 115VAC +/- 5% | 115VAC +/- 5% |
| AC output Frequency | 60Hz +/- 1Hz | 60Hz +/- 1Hz | 60Hz +/- 1Hz | 60Hz +/- 1Hz |
| AC output waveform | Modified sine wave | Modified sine wave | Modified sine wave | Modified sine wave |
| Optimum efficiency | 90% | 90% | 90% | 90% |
| No load current drive | < 0.3 A DC | < 0.3 A DC | < 0.6 A DC | < 0.6 A DC |
| Input voltage range | 10.5 - 15.5 VDC | 10.5 - 15.5 VDC | 10.5 - 15.5 VDC | 10.5 - 15.5 VDC |
| General Specifications | ||||
| Operating temperature range |
32°F − 104°F / 0°C − 40 °C |
|||
| AC receptacles | 2 | 2 | 2 | 4 |
| Dimensions(HxWxL) | 2.8 x 5.9 x 12.3" | 3 x 5.9 x 15" | 4.3 x 9.5 x 18.5" | 6.25 x 8 x 19.5" |
| Weight | 4.4Lbs | 5.9Lbs | 12.9lbs | 24.1 Lbs |
| Warranty | 1 year | 1 year | 1 year | 1 year |
| Part Number | 813-1000-UL | 813-1500-UL | 813-3000-UL | 813-5000 |